OSRAM AirZing PRO 5030 - 30W UV-C Luminaire with IR Sensor for Air and Surface Disinfection (253.7 nm)

In stock
SKU: AIRZING5030 EAN13: 4062172156622
Regular price 38,10 € inc. VAT

If you have any questions about this product, we can assist you by filling out the contact form

OSRAM AirZing PRO 5030 - 30W UV-C Luminaire with IR Sensor for Air and Surface Disinfection (253.7 nm)

The OSRAM AirZing PRO 5030 is a UV-C germicidal luminaire for wall or ceiling mounting, designed to deactivate microorganisms in the air and on surfaces in unoccupied indoor spaces. It integrates a 30W PURITEC® HNS® T8 lamp with 253.7 nm emission (ozone-free), an infrared presence sensor that switches off the unit upon detecting the entry of people or animals, and a 30-second start-up delay for enhanced safety. With a UV-C output of 11–12W and a reference irradiance of >1.2W/m² @ 1m (initial) and >0.96W/m² @ 1m at 9,000 h, it allows for controlled dose adjustment (irradiance × time) based on height, distance, and shadows.

It operates at 220 V ±10% (50/60 Hz) with a system power of approximately 34 W , THD < 20% , and a power factor ≥ 0.9 . Its dimensions of 1058 × 54 × 78 mm and weight of approximately 1.3 kg facilitate installation at heights of 2.5–4 m . It is not for general lighting; it is intended for programmed cycles without occupancy , with appropriate signaling and access control.

Main features

  • UV-C source: OSRAM PURITEC® HNS® T8 30 W (G13), 253.7 nm, ozone free.
  • UV-C flux: 11–12 W; reference irradiance: >1.2 W/m² @1 m (initial) and >0.96 W/m² @1 m 9,000 h.
  • Integrated safety: IR presence sensor (immediate shutdown) and 30s power-on delay; manual restart after detection.
  • Input: 220 V ±10%, 50/60 Hz; system power: ≈ 34 W; THD: <20%; PF: ≥ 0.9; Lamp current: 360 mA.
  • Construction: 1058 × 54 × 78 mm; ≈ 1.3 kg; for indoor use.
  • Recommended height: 2.5–4 m; wall or ceiling mounting (brackets included).
  • Lamp life: 9,000 h.

Product benefits

  • Chemical-free disinfection of air and surfaces: UV-C radiation at 253.7 nm alters DNA/RNA and prevents microbial replication.
  • Safe and controlled operation thanks to the IR sensor, the power-on delay and the need for manual restart after detection.
  • Reproducible results with specified flux and irradiance values ​​to calculate dose and times.
  • Easy integration into interior spaces due to its linear format and electronics optimized for the 30W HNS lamp.

Use cases

  • Rooms, corridors and toilets in offices, shops and hospitality (scheduled cycles without presence).
  • Lobbies, waiting rooms and common areas with intermittent traffic.
  • Warehouses and technical rooms where a reduction of microbial load on visible surfaces is required.

Guide to installation times (installation height 3 m)

  • Up to 8 m²: 30 min
  • 8–12 m²: 45 min
  • 12–15 m²: 60 min
  • >15 m²: install multiple units

Effectiveness depends on the UV-C dose (irradiance × time), the line of sight , and shadows. Adjust height, number of units, and cycles according to the room layout.

Frequently Asked Questions

  • Can it operate with people present? No. UV-C light can damage skin and eyes. This light fixture is designed to operate only when unoccupied ; the IR sensor turns off the system if it detects movement.
  • Does it turn itself back on after detection? No. It requires a manual reset once the area is cleared.
  • Does it generate ozone? No. The HNS lamp emits at ~254 nm and is ozone-free .
  • How do I check the irradiance? After 5 minutes of stabilization, measure at 1 m with a UV-C radiometer. For reference, typical initial values ​​are >1.2 W/m² @ 1 m and >0.96 W/m² at 9,000 h.

Safety information and warnings

  • For UV-C disinfection only; not for general lighting .
  • Signpost and block access points during the cycle; keep doors/windows closed and avoid drafts.
  • Polymeric materials can degrade from prolonged UV-C exposure; protect them when necessary.
  • Installation and maintenance by qualified personnel; use appropriate eye and skin protection.
  • The lamp contains mercury (Hg); dispose of waste according to local regulations.

Project description

OSRAM AirZing PRO 5030 indoor UV-C luminaire; PURITEC® HNS® T8 30 W (G13) lamp, 253.7 nm, ozone-free; UV-C flux 11–12 W ; irradiance >1.2 W/m² @1 m (initial) and >0.96 W/m² @1 m 9,000 h; input 220 V ±10 % (50/60 Hz); system power ≈ 34 W; THD <20 %; PF ≥ 0.9; lamp current 360 mA; IR presence sensor with immediate switch-off and 30 s start-up delay; installation 2.5–4 m; dimensions 1058 × 54 × 78 mm; weight ≈ 1.3 kg.

  • Brand:OSRAM
  • Model:AirZing PRO 5030
  • Guy:UV-C germicidal luminaire for air and surfaces (indoor use)
  • Wavelength:253.7 nm (ozone-free)
  • Lamp included:PURITEC® HNS® T8 30 W (G13)
  • UV-C flux:11–12 W
  • Reference irradiance:>1.2 W/m² @1 m (initial); >0.96 W/m² @1 m to 9,000 h
  • Lamp lifespan:9,000 h
  • Input voltage:220 V ±10% (198–242 V), 50/60 Hz
  • System power:≈ 34 W
  • THD:<20%
  • Power factor:≥ 0.9
  • Lamp current:360 mA
  • Recommended installation height:2.5–4 m
  • Approximate times (h=3 m):<8 m² → 30 min; 8–12 m² → 45 min; 12–15 m² → 60 min; >15 m² → multiple units
  • Dimensions (L×W×H):1058 × 54 × 78 mm
  • Weight:≈ 1.3 kg
  • Around:Indoor use; typical operating temperature −10…+40 °C; storage temperature −20…+60 °C
  • Security:IR sensor, automatic power-off upon presence, 30s power-on delay; manual restart after detection
  • Mounting:wall or ceiling; brackets included
  • Observations:Operate only when no people/animals are present; it is not general lighting.
  • Supply unit:1 unit
  • Vendor OSRAM
  • SKU AIRZING5030
  • Bar-code 4062172156622