OSRAM XBO 100 W OFR - Short Arc Xenon Lamp (Double Terminal) for Endoscopy, Microscopy and Fiber Optics

Out of stock
SKU: 003-2201 EAN13: 4008321386328
Regular price 443,67 € inc. VAT

Gastos de envío, si aplican, calculados al finalizar la compra.

Devolución en 14 días
Pago seguro y cifrado
3 años garantía*

Métodos de pago
  • Apple Pay
  • Google Pay
  • Maestro
  • Mastercard
  • MobilePay
  • Shop Pay
  • Visa

También aceptamos transferencia bancaria

If you have any questions about this product, we can assist you by filling out the contact form

OSRAM XBO 100 W OFR - Short Arc Xenon Lamp (Double Terminal) for Endoscopy, Microscopy and Fiber Optics

The OSRAM XBO 100 W OFR is a 100 W short-arc xenon lamp with terminals at both ends, designed to deliver extremely high luminance from a point source and a continuous spectrum in the visible range. It provides a color temperature of ~6000 K (daylight) with a CRI Ra 98 , instant start , hot restart , and wide-range dimming . The OFR version uses special quartz that blocks the 185 nm line to prevent ozone formation. Its compact geometry and arc stability make it the ideal choice for endoscopy , microscopy , surgical headlamps , fiber optic illumination , as well as solar simulation and R&D imaging/scanning .

Main features

  • Professional light quality: ~ 6000 K (daylight) and CRI Ra 98 constant throughout its lifespan.
  • High luminance point source: very stable arc for efficient coupling to fiber and optics.
  • Flexible operation: dimmable , instant start and hot restart .
  • OFR (ozone-free) version: quartz that suppresses ozone formation.
  • Robust and compact construction: Ø 11 mm , length 90 mm , LCL 44.5 mm , weight ~12 g .

Product benefits

  • Stable and reliable color: homogeneous daylight and reference color reproduction for critical vision and image capture.
  • Quality uniformity: consistency between lamps and different power levels within the XBO family.
  • Productivity: hot restart and regulation to adapt to the procedure without waiting.
  • Long service life for its category: up to 500 h (reference conditions).

Use cases

  • Health and science: light sources for endoscopy , microscopy and surgical headlamps .
  • Industry and R&D: fiber optic lighting , low-power solar simulation , imaging and scanning .

Frequently Asked Questions

  • Does it need a specific power supply? Yes. It requires DC power with a stabilized current according to the lamp's electrical specifications.
  • Does it generate ozone? No. The OFR version uses quartz, which blocks the radiation responsible for forming ozone.
  • How should it be mounted? Position s100 : if installed vertically, anode up ; up to 10° below the horizontal, cathode up .
  • What type of cooling is required? Convection (according to the data sheet). Ensure proper ventilation of the compartment.
  • Is it safe in the open? It must be operated in enclosed housings due to its high luminance, UV radiation, and high internal pressure; always use protective covers during handling.

Installation and safety

  • Respect the electrical parameters : 12.8–14.4 V DC and 7.0–7.4 A (100 W nominal).
  • Avoid touching the quartz; use PPE and the supplied covers .
  • Check the polarity and correct seating of the SFa7.5-2 (cathode) / SFa9-2 (anode) bases.
  • Ensure ventilation and protection against UV/IR and fragmentation in case of breakage.

Project description

OSRAM XBO 100 W OFR (double terminal) short arc xenon lamp; 100 W ; DC ; Lamp voltage 12.8–14.4 V (start); Lamp current 7.0–7.4 A ; ~6000 K ; CRI Ra 98 ; Flux 1900 lm (typical start value) and intensity 270 cd ; LCL 44.5 mm ; Ø 11 mm ; Length 90 mm ; Weight ~12 g ; Bases SFa7.5-2 (cathode) and SFa9-2 (anode); Position s100 (if vertical, anode up; up to 10° below horizontal, cathode up); Hot restrike , dimmable , convection cooling ; Average life 500 h ; OFR (ozone-free) version .

  • Brand:OSRAM
  • Model:XBO 100 W OFR
  • Technology:Short arc xenon lamp (double terminal)
  • Version:OFR (ozone-free)
  • Nominal power:100 W
  • Lamp voltage (start):12.8–14.4 V CC
  • Lamp current:7.0–7.4 A
  • Type of current:Direct current (DC)
  • Nominal luminous flux:1900 lm (typical initial value)
  • Luminous intensity:270 cd (typical initial value)
  • Color temperature (CCT):~6000 K (natural light)
  • Color Rendering Index (CRI):Ra 98
  • Luminous center length (LCL):44.5 mm
  • Diameter:11.0 mm
  • Total length:90.0 mm
  • Approximate weight:12 g
  • Base (anode):SFa9-2
  • Base (cathode):SFa7.5-2
  • Electrode gap (cold):0.9 mm
  • Job position:s100 (if vertical, anode up; up to 10° below horizontal, cathode up)
  • Hot restart:Yeah
  • Dimming:Yes, wide range.
  • Refrigeration:By convection
  • Average lifespan:500 h
  • Applications:Endoscopy, microscopy, surgical headlamps, fiber optic illumination, solar simulation, imaging and scanning
  • Type Short Bow
  • Vendor OSRAM
  • SKU 003-2201
  • Bar-code 4008321386328