OSRAM HNS 30 W G13 (PURITEC UV-C) - T8 254 nm OFR germicidal tube for disinfection of air, water and surfaces

In stock
SKU: 003-770301 EAN13: 4008321770301
Regular price 9,17 € inc. VAT

If you have any questions about this product, we can assist you by filling out the contact form

OSRAM HNS 30 W G13 (PURITEC UV-C) - T8 254 nm OFR germicidal tube for disinfection of air, water and surfaces

The OSRAM HNS 30 W G13 is a low-pressure UV-C germicidal lamp in a T8 format (Ø 26 mm) designed for effective chemical-free disinfection . It belongs to the PURITEC HNS family and emits radiation with a dominant wavelength of 254 nm in an OFR (ozone-free) version, thanks to a special glass that blocks the 185 nm line to prevent ozone generation. With 30 W of electrical power, a nominal voltage of 96 V , and a G13 base, it delivers a typical UV-C radiated power of ~12 W , suitable for inactivating microorganisms in air , water , and surface purification systems. Its specific internal coating maintains stable UV-C emission and extends its lifespan. It is not dimmable and its working position is universal . Total length: 895 mm . Reference nominal lifespan: 9,000 h . For exclusive use in equipment designed for UV-C with appropriate protective measures.

Main features

  • Technology: Low pressure UV-C germicidal lamp, T8 tube.
  • Spectrum: 254 nm dominant ( OFR , ozone free).
  • Electrical power: 30 W · Nominal voltage: 96 V · Nominal current: 0.36–0.40 A (according to data sheet).
  • Base: G13 (bi-pin).
  • Dimensions: diameter 26.0 mm · length 895.0 mm.
  • UV-C radiated power (200–280 nm): approx. 12 W.
  • Luminous intensity (photometric data): 7,800 cd.
  • Job position: any (universal).
  • Adjustable: no.
  • Construction: low mercury content and specific coating for greater durability.
  • Reference nominal life: 9,000 h.
  • Application: disinfection of air, water and surfaces in professional equipment.

Product benefits

  • Efficient disinfection without chemicals , minimizing waste in sanitary and industrial processes.
  • Ozone-free OFR version for integration into closed systems or with controlled extraction.
  • Stable UV-C emission throughout the life cycle thanks to the internal coating.
  • Standard T8 format with G13 base , facilitates replacement in compatible equipment.
  • Versatile installation due to its universal working position.

Use cases

  • Air purification in HVAC ducts, upper-room chambers and stand-alone units with UV-C shielding.
  • Water treatment in quartz jacketed equipment (reservoirs, fountains, aquaculture, industrial processes).
  • Disinfection of surfaces in transport tunnels, processing chambers and laboratories.
  • Sanitary and industrial applications that require microbiological control without chemical agents.

Frequently Asked Questions

  • Does it generate ozone? No. The OFR version blocks the 185 nm line responsible for ozone formation.
  • Can it be used with people present? No. UV-C radiation can damage skin and eyes. Use enclosed housings, interlocks, and signage.
  • Does it need a ballast? Yes. It requires high-load T8 electronic ballasts. Typical example: QUICKTRONIC PROFESSIONAL QTP-OPTIMAL 1x18–40 (or other equivalent ballasts depending on the equipment design).
  • Is it adjustable? No.
  • How to manage maintenance? UV-C irradiance decreases over time; plan replacements according to the system's dose target.

Installation and safety recommendations

  • Integrate UV-C shielding , interlocks, timers and signaling in accordance with regulations.
  • In water treatment, use a clean quartz jacket and perform regular maintenance to ensure optical transmission.
  • Avoid dust or grease on the tube; clean in cold water with a soft cloth and isopropyl alcohol.
  • End of life: manage as waste with mercury content (low content).

Technical note on nominal values

The most recent OSRAM documentation (2025) specifies a lifespan of 9,000 hours and a nominal current of 0.40 A , while LEDVANCE datasheets (2023) list 8,000 hours and 0.36 A. Therefore, ranges are shown where applicable. The UV-C radiated power (~12 W) and dimensions (T8, 26 mm × 895 mm) remain constant across datasheets.

Project description

Low-pressure UV-C germicidal lamp, PURITEC HNS series; model HNS 30 W G13; T8 tube Ø 26.0 mm; length 895.0 mm; base G13; electrical power 30 W; nominal voltage 96 V; nominal current 0.36–0.40 A; dominant emission 254 nm (OFR, ozone-free); UV-C radiated power approx. 12 W; luminous intensity 7,800 cd; universal working position; non-dimmable; reference nominal life 9,000 h.

  • Brand:OSRAM
  • Model:HNS 30 W G13 (PURITEC UV-C)
  • Family:PURITEC HNS (UV-C germicidal lamps)
  • Technology:Low pressure UV-C lamp, T8 tube
  • Version:OFR (ozone-free), dominant wavelength 254 nm
  • Electrical power:30 W
  • Nominal voltage:96 V
  • Nominal current:0.36–0.40 A (according to data sheet)
  • Base:G13 (bi-pin)
  • Tube diameter:26.0 mm
  • Tube length:895.0 mm
  • UV-C radiated power (200–280 nm):~12 W
  • Luminous intensity (photometric data):7,800 cd
  • Job position:Anyone (universal)
  • Adjustable:No
  • Nominal reference life:9,000 h
  • Approximate weight:140 g
  • Equipment compatibility:ECG for T8 30 W; p. e.g. QUICKTRONIC PROFESSIONAL QTP-OPTIMAL 1x18–40 (or equivalent)
  • Unit of sale:1 piece
  • Complete packaging:25 units
  • Areas of application:Disinfection of air, water and surfaces
  • Safety warnings:Emits high-intensity UV-C; avoid direct or reflected exposure of skin and eyes
  • Type Medicine
  • Vendor OSRAM
  • SKU 003-770301
  • Bar-code 4008321770301

Buy OSRAM HNS 30 W G13 (PURITEC UV-C) - T8 254 nm OFR germicidal tube for disinfection of air, water and surfaces